Wed, 10 Jun 2020 09:43:51 +0200
SDK settings to reduce bin size. Some log messages to debug level. Added KWH usage registration. Added equipment power usage for HLT and MLT. Equipment database upgraded to version 2, expandable. Fixed some screen errors during temperature mash steps.
0 | 1 | menu "BrewBoard Configuration" |
2 | ||
3 | ||
4 | choice TEMP_SENSORS | |
5 | prompt "Select Temperature Sensors" | |
6 | default TEMP_SENSORS_ONEWIRE | |
7 | help | |
8 | Select to use Real or Fake Temperature Sensors | |
9 | ||
10 | config TEMP_SENSORS_ONEWIRE | |
11 | bool "Real Sensors" | |
12 | help | |
13 | Select this to use real Sensors connected on the One-Wire busses | |
14 | ||
15 | config TEMP_SENSORS_SIMULATOR | |
16 | bool "Fake Sensors" | |
17 | help | |
18 | Select this to use Fake Sensors for development | |
19 | ||
20 | endchoice | |
21 | ||
22 | ||
23 | config ONE_WIRE_MLT | |
24 | int "OneWire MLT GPIO number" | |
25 | range 0 34 | |
26 | default 27 | |
27 | depends on TEMP_SENSORS_ONEWIRE | |
28 | help | |
29 | GPIO number (IOxx) to access the DS18B20 for the MLT and Boil kettle. | |
30 | ||
31 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used. | |
32 | ||
33 | GPIOs 35-39 are input-only so cannot be used to drive the One Wire Bus. | |
34 | ||
35 | config ONE_WIRE_HLT | |
36 | int "OneWire HLT GPIO number" | |
37 | range 0 34 | |
38 | default 26 | |
39 | depends on TEMP_SENSORS_ONEWIRE | |
40 | help | |
41 | GPIO number (IOxx) to access the DS18B20 for the HLT kettle. | |
42 | ||
43 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used. | |
44 | ||
45 | GPIOs 35-39 are input-only so cannot be used to drive the One Wire Bus. | |
46 | ||
47 | config SSR_MLT_GPIO | |
48 | int "MLT SSR GPIO number" | |
49 | range 0 34 | |
74
cba50f7529d0
Version 0.3.8. Switched build system to idf.py
Michiel Broek <mbroek@mbse.eu>
parents:
0
diff
changeset
|
50 | default 32 |
0 | 51 | help |
52 | GPIO number (IOxx) to the SSR for the MLT kettle. | |
53 | ||
54 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used to drive a SSR. | |
55 | ||
56 | GPIOs 35-39 are input-only so cannot be used as outputs. | |
57 | ||
58 | config SSR_HLT_GPIO | |
59 | int "HLT SSR GPIO number" | |
60 | range 0 34 | |
74
cba50f7529d0
Version 0.3.8. Switched build system to idf.py
Michiel Broek <mbroek@mbse.eu>
parents:
0
diff
changeset
|
61 | default 33 |
0 | 62 | help |
63 | GPIO number (IOxx) to the SSR for the HLT kettle. | |
64 | ||
65 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used to drive a SSR. | |
66 | ||
67 | GPIOs 35-39 are input-only so cannot be used as outputs. | |
68 | ||
69 | config SSR_PUMP_GPIO | |
70 | int "PUMP SSR GPIO number" | |
71 | range 0 34 | |
72 | default 12 | |
73 | help | |
74 | GPIO number (IOxx) to the SSR for the Pump. | |
75 | ||
76 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used to drive a SSR. | |
77 | ||
78 | GPIOs 35-39 are input-only so cannot be used as outputs. | |
79 | ||
80 | ||
81 | config BUZZER_GPIO | |
82 | int "Piezo Buzzer GPIO number" | |
83 | range 0 34 | |
84 | default 25 | |
85 | help | |
86 | GPIO number (IOxx) to the Piezo Buzzer. | |
87 | ||
88 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used to drive a SSR. | |
89 | ||
90 | GPIOs 35-39 are input-only so cannot be used as outputs. | |
91 | ||
92 | ||
93 | endmenu |