Mon, 22 Oct 2018 21:43:45 +0200
Updated esp-ide. Removed VNC server corre encoding because no clients would use it. Enabled WiFi error logmessages. Write runtime record is now debug logging. Removed recipe.Record number, not usefull and was wrong too. Removed console print of json log data.
0 | 1 | menu "BrewBoard Configuration" |
2 | ||
3 | ||
4 | choice TEMP_SENSORS | |
5 | prompt "Select Temperature Sensors" | |
6 | default TEMP_SENSORS_ONEWIRE | |
7 | help | |
8 | Select to use Real or Fake Temperature Sensors | |
9 | ||
10 | config TEMP_SENSORS_ONEWIRE | |
11 | bool "Real Sensors" | |
12 | help | |
13 | Select this to use real Sensors connected on the One-Wire busses | |
14 | ||
15 | config TEMP_SENSORS_SIMULATOR | |
16 | bool "Fake Sensors" | |
17 | help | |
18 | Select this to use Fake Sensors for development | |
19 | ||
20 | endchoice | |
21 | ||
22 | ||
23 | config ONE_WIRE_MLT | |
24 | int "OneWire MLT GPIO number" | |
25 | range 0 34 | |
26 | default 27 | |
27 | depends on TEMP_SENSORS_ONEWIRE | |
28 | help | |
29 | GPIO number (IOxx) to access the DS18B20 for the MLT and Boil kettle. | |
30 | ||
31 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used. | |
32 | ||
33 | GPIOs 35-39 are input-only so cannot be used to drive the One Wire Bus. | |
34 | ||
35 | config ONE_WIRE_HLT | |
36 | int "OneWire HLT GPIO number" | |
37 | range 0 34 | |
38 | default 26 | |
39 | depends on TEMP_SENSORS_ONEWIRE | |
40 | help | |
41 | GPIO number (IOxx) to access the DS18B20 for the HLT kettle. | |
42 | ||
43 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used. | |
44 | ||
45 | GPIOs 35-39 are input-only so cannot be used to drive the One Wire Bus. | |
46 | ||
47 | config SSR_MLT_GPIO | |
48 | int "MLT SSR GPIO number" | |
49 | range 0 34 | |
50 | default 33 | |
51 | help | |
52 | GPIO number (IOxx) to the SSR for the MLT kettle. | |
53 | ||
54 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used to drive a SSR. | |
55 | ||
56 | GPIOs 35-39 are input-only so cannot be used as outputs. | |
57 | ||
58 | config SSR_HLT_GPIO | |
59 | int "HLT SSR GPIO number" | |
60 | range 0 34 | |
61 | default 32 | |
62 | help | |
63 | GPIO number (IOxx) to the SSR for the HLT kettle. | |
64 | ||
65 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used to drive a SSR. | |
66 | ||
67 | GPIOs 35-39 are input-only so cannot be used as outputs. | |
68 | ||
69 | config SSR_PUMP_GPIO | |
70 | int "PUMP SSR GPIO number" | |
71 | range 0 34 | |
72 | default 12 | |
73 | help | |
74 | GPIO number (IOxx) to the SSR for the Pump. | |
75 | ||
76 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used to drive a SSR. | |
77 | ||
78 | GPIOs 35-39 are input-only so cannot be used as outputs. | |
79 | ||
80 | ||
81 | config BUZZER_GPIO | |
82 | int "Piezo Buzzer GPIO number" | |
83 | range 0 34 | |
84 | default 25 | |
85 | help | |
86 | GPIO number (IOxx) to the Piezo Buzzer. | |
87 | ||
88 | Some GPIOs are used for other purposes (flash connections, etc.) and cannot be used to drive a SSR. | |
89 | ||
90 | GPIOs 35-39 are input-only so cannot be used as outputs. | |
91 | ||
92 | ||
93 | endmenu |