Reverted gpio_pad_select_gpio() calls, added the correct include. Starting the unit works better now. Reverted some other small changes. In some parts the controller is very slow, possible spiffs issue? idf 5.1 tip

tag release 0.3.25 default

Removed tag help rel-0.3.25

Added tag help for changeset 9fb33533504a

Version 0.3.25. Larger partitions for the binary. Added UPGRADE.md with information for this upgrade.

IDF code size optimisations, reduced binary 157.379 bytes. Now it fits in the partitions. idf 5.1

Added new files and remove obsolete. idf 5.1

Start migration to IDF 5.1 idf 5.1

Fix current year display

Version 0.3.24. Kicad upgrade affecting schema's. A recipe with a single mashstep, the step was treated as a mashout and the wrong temperature range was applied.

Version 0.3.23. In a decoction mash step during wait for confirm prompt, leave the setpoint as it was. Set the new temperature after confirmation. Log this.

Some kicad upgrade, no project changes.

Version 0.3.22. Fixed adding Tetra Hop, it is now not added to the recipe because this hop is not added on brewday.

Updated kicad drawings to kicad 6.0.8

Upgraded kicad to version 6

Version 0.3.21. Changed HLT heatup speed calculation to 0.67 degrees/minute. Include the mash ramp times in the calculation for the initial temperature. With a combined HLT and MLT setup, the HLT preheat time is now much shorter. Fixed problems reading beerxml if there is an aroma hop. If the time was 0 or missing it was assumed to be a whirlpool hop. Now it's treated as flameout hop as it should be. Fixed sorting hop/misc additions, this could lead to missing ingredients warnings. The recipe cool temperature was treated as an integer value.

Version 0.3.20 fix for equipment records create and delete.

Version 0.3.19. Real sensors and code cleanup.

Updated the README

Removed Delay Start code leftovers.

Fixed Hendi ON switch and now the switch moment is in a #define HENDI_SWITCH. Currently set at 6. Fixed the web page when going to boil, two buttons were missing. Changed the PWM log line, added information about the ON switch and current temperature.

Version 0.3.18

Fixed Brewfather beerxml import.

Fixed KWh measurement for Hendi equipment.

Removed the 1024 - again.

Revised the equipment edit screen, order is more logical. Changed some label names. Made room for one more setting.

Changed PWM power calculation during PID use.

Version 0.3.17. Made the Hendi PWM change official.

(0) -100 -50 -28 tip

mercurial