Fix current year display default tip

Version 0.3.24. Kicad upgrade affecting schema's. A recipe with a single mashstep, the step was treated as a mashout and the wrong temperature range was applied.

Version 0.3.23. In a decoction mash step during wait for confirm prompt, leave the setpoint as it was. Set the new temperature after confirmation. Log this.

Some kicad upgrade, no project changes.

Version 0.3.22. Fixed adding Tetra Hop, it is now not added to the recipe because this hop is not added on brewday.

Updated kicad drawings to kicad 6.0.8

Upgraded kicad to version 6

Version 0.3.21. Changed HLT heatup speed calculation to 0.67 degrees/minute. Include the mash ramp times in the calculation for the initial temperature. With a combined HLT and MLT setup, the HLT preheat time is now much shorter. Fixed problems reading beerxml if there is an aroma hop. If the time was 0 or missing it was assumed to be a whirlpool hop. Now it's treated as flameout hop as it should be. Fixed sorting hop/misc additions, this could lead to missing ingredients warnings. The recipe cool temperature was treated as an integer value.

Version 0.3.20 fix for equipment records create and delete.

Version 0.3.19. Real sensors and code cleanup.

Updated the README

Removed Delay Start code leftovers.

Fixed Hendi ON switch and now the switch moment is in a #define HENDI_SWITCH. Currently set at 6. Fixed the web page when going to boil, two buttons were missing. Changed the PWM log line, added information about the ON switch and current temperature.

Version 0.3.18

Fixed Brewfather beerxml import.

Fixed KWh measurement for Hendi equipment.

Removed the 1024 - again.

Revised the equipment edit screen, order is more logical. Changed some label names. Made room for one more setting.

Changed PWM power calculation during PID use.

Version 0.3.17. Made the Hendi PWM change official.

Inverted PWM signal for the Hendi.

Versie 0.3.16

Schema aangepast voor pullup weerstanden voor de SD kaart. Code verbeteringen in task_sdcard.

SD card completly switched to the SPI driver API.

Version 0.3.15. Back to real sensors. During cooling the target temperature is changed in 0.5 degrees steps instead of whole degrees.

Default equipment max_watt set to 2750. Added defaults for new equipment record. Switched PWM timer to high-speed. Implemented the safety timer to prevent the MLT + HLT will draw too much power in shared mode. Removed some code ideas that were not used. The fake heater now uses the faked PWM power.

Finished experimental code to drive the German HendiControl board. Added BoilPower and RampPower buttons during the while boil process. RampPower (going to boil power) is now adjustable. Added PWM driver code to the driver task.

Fixed HendiControl interface connecter to match the board input. Tested the new circuit.

Added more modules local.

Added ESP32 library inside the project.

(0) -100 -50 -30 tip