changelog
- Thu, 06 Oct 2022 14:17:05 +0200
- by Michiel Broek <mbroek@mbse.eu> [Thu, 06 Oct 2022 14:17:05 +0200] rev 124
- Version 0.3.22. Fixed adding Tetra Hop, it is now not added to the recipe because this hop is not added on brewday.
- Sat, 01 Oct 2022 14:23:15 +0200
- by Michiel Broek <mbroek@mbse.eu> [Sat, 01 Oct 2022 14:23:15 +0200] rev 123
- Updated kicad drawings to kicad 6.0.8
- Mon, 26 Sep 2022 22:17:35 +0200
- by Michiel Broek <mbroek@mbse.eu> [Mon, 26 Sep 2022 22:17:35 +0200] rev 122
- Upgraded kicad to version 6
- Sat, 25 Jun 2022 15:24:55 +0200
- by Michiel Broek <mbroek@mbse.eu> [Sat, 25 Jun 2022 15:24:55 +0200] rev 121
- Version 0.3.21. Changed HLT heatup speed calculation to 0.67 degrees/minute. Include the mash ramp times in the calculation for the initial temperature. With a combined HLT and MLT setup, the HLT preheat time is now much shorter. Fixed problems reading beerxml if there is an aroma hop. If the time was 0 or missing it was assumed to be a whirlpool hop. Now it's treated as flameout hop as it should be. Fixed sorting hop/misc additions, this could lead to missing ingredients warnings. The recipe cool temperature was treated as an integer value.
- Tue, 02 Nov 2021 14:47:43 +0100
- by Michiel Broek <mbroek@mbse.eu> [Tue, 02 Nov 2021 14:47:43 +0100] rev 120
- Version 0.3.20 fix for equipment records create and delete.
- Sat, 31 Jul 2021 15:44:20 +0200
- by Michiel Broek <mbroek@mbse.eu> [Sat, 31 Jul 2021 15:44:20 +0200] rev 119
- Version 0.3.19. Real sensors and code cleanup.
- Fri, 30 Jul 2021 20:35:04 +0200
- by Michiel Broek <mbroek@mbse.eu> [Fri, 30 Jul 2021 20:35:04 +0200] rev 118
- Updated the README
- Fri, 30 Jul 2021 19:39:02 +0200
- by Michiel Broek <mbroek@mbse.eu> [Fri, 30 Jul 2021 19:39:02 +0200] rev 117
- Removed Delay Start code leftovers.
- Fri, 30 Jul 2021 16:45:53 +0200
- by Michiel Broek <mbroek@mbse.eu> [Fri, 30 Jul 2021 16:45:53 +0200] rev 116
- Fixed Hendi ON switch and now the switch moment is in a #define HENDI_SWITCH. Currently set at 6. Fixed the web page when going to boil, two buttons were missing. Changed the PWM log line, added information about the ON switch and current temperature.
- Thu, 29 Jul 2021 22:38:30 +0200
- by Michiel Broek <mbroek@mbse.eu> [Thu, 29 Jul 2021 22:38:30 +0200] rev 115
- Version 0.3.18
- Thu, 29 Jul 2021 22:36:17 +0200
- by Michiel Broek <mbroek@mbse.eu> [Thu, 29 Jul 2021 22:36:17 +0200] rev 114
- Fixed Brewfather beerxml import.
- Thu, 29 Jul 2021 19:57:41 +0200
- by Michiel Broek <mbroek@mbse.eu> [Thu, 29 Jul 2021 19:57:41 +0200] rev 113
- Fixed KWh measurement for Hendi equipment.
- Wed, 28 Jul 2021 22:04:54 +0200
- by Michiel Broek <mbroek@mbse.eu> [Wed, 28 Jul 2021 22:04:54 +0200] rev 112
- Removed the 1024 - again.
- Wed, 28 Jul 2021 20:42:30 +0200
- by Michiel Broek <mbroek@mbse.eu> [Wed, 28 Jul 2021 20:42:30 +0200] rev 111
- Revised the equipment edit screen, order is more logical. Changed some label names. Made room for one more setting.
- Wed, 28 Jul 2021 17:12:00 +0200
- by Michiel Broek <mbroek@mbse.eu> [Wed, 28 Jul 2021 17:12:00 +0200] rev 110
- Changed PWM power calculation during PID use.
- Sun, 18 Jul 2021 11:25:55 +0200
- by Michiel Broek <mbroek@mbse.eu> [Sun, 18 Jul 2021 11:25:55 +0200] rev 109
- Version 0.3.17. Made the Hendi PWM change official.
- Sat, 17 Jul 2021 20:21:02 +0200
- by Michiel Broek <mbroek@mbse.eu> [Sat, 17 Jul 2021 20:21:02 +0200] rev 108
- Inverted PWM signal for the Hendi.
- Mon, 05 Jul 2021 10:31:38 +0200
- by Michiel Broek <mbroek@mbse.eu> [Mon, 05 Jul 2021 10:31:38 +0200] rev 107
- Versie 0.3.16
- Mon, 05 Jul 2021 10:30:05 +0200
- by Michiel Broek <mbroek@mbse.eu> [Mon, 05 Jul 2021 10:30:05 +0200] rev 106
- Schema aangepast voor pullup weerstanden voor de SD kaart. Code verbeteringen in task_sdcard.
- Thu, 01 Jul 2021 20:26:45 +0200
- by Michiel Broek <mbroek@mbse.eu> [Thu, 01 Jul 2021 20:26:45 +0200] rev 105
- SD card completly switched to the SPI driver API.
- Tue, 22 Jun 2021 23:06:41 +0200
- by Michiel Broek <mbroek@mbse.eu> [Tue, 22 Jun 2021 23:06:41 +0200] rev 104
- Version 0.3.15. Back to real sensors. During cooling the target temperature is changed in 0.5 degrees steps instead of whole degrees.
- Tue, 22 Jun 2021 22:21:09 +0200
- by Michiel Broek <mbroek@mbse.eu> [Tue, 22 Jun 2021 22:21:09 +0200] rev 103
- Default equipment max_watt set to 2750. Added defaults for new equipment record. Switched PWM timer to high-speed. Implemented the safety timer to prevent the MLT + HLT will draw too much power in shared mode. Removed some code ideas that were not used. The fake heater now uses the faked PWM power.
- Mon, 21 Jun 2021 19:04:10 +0200
- by Michiel Broek <mbroek@mbse.eu> [Mon, 21 Jun 2021 19:04:10 +0200] rev 102
- Finished experimental code to drive the German HendiControl board. Added BoilPower and RampPower buttons during the while boil process. RampPower (going to boil power) is now adjustable. Added PWM driver code to the driver task.
- Sat, 19 Jun 2021 20:46:42 +0200
- by Michiel Broek <mbroek@mbse.eu> [Sat, 19 Jun 2021 20:46:42 +0200] rev 101
- Fixed HendiControl interface connecter to match the board input. Tested the new circuit.