Added web page to display the one-wire bus live status.

Final 0.9.19a3 change.

Version 0.9.19a3. Fixed segfault in onewire temperature measurement. Fixed json error in onewire device.

Version 0.9.19a2. Dropped TEMPSTATE[] and only use DEVPRESENT[] to mark devices state. Adjusted webpages for this switch in responses. Adjusted MySQL mon_fermenters enum values too. Rename some global Config records to better reflect their real use.Added one-wire json records and websocket. Announce when some onewire device changes. Add UNITS JSON command without parameter. Dropped global tempFormat setting that was never used.

Fixed two compiler warnings on arm platform

Version 0.9.19a1

Better handling of a removed DS18B20 temperature sensor.

Create global_json() for all and expanded the data to the complete setup. Added design for the global setup.

More copyright references.

Devices edit popup layout ready.

More work for devices list and editor.

Devices list grid added.

Updated dependencies. Devices json data is created in de devices source for all places where it is needed. Added devices_ws function to broadcast all devices, to be used when any device is changed. The devices loop detects changes in input values and calls devices_ws if so. The server uses the general devices json data.

Fixed fermenter switches in NONE mode. Som other small bugfixes.

Websocket ping/pong uses sequence numbers.

Minor details for server DEVICE commands. Added getdevice<s> php scripts.

Increased server buffersize from 1024 to 4096. Added DEVICE JSON <uuid> command. Added websocket response fermenter profile. The fermenter monitor screen is ready (maybe).

Added getglobal.php script

Better websocket broadcast messages. Added GLOBAL JSON command to the server. Better logic to trigger websocket and mqtt data updates for the fermenter units. Websocket receive added fermenter mode, stage, setpoints, switches. Added more css styles for the fermenter screen. Added the fermenter screen php and javascript.

Server json unit data list added

Add stylesheet, about page. Add menu for fermenters. Add websocket port setup to the config server.

Added websockets to thermferm. Started new www directory for websocket enabled web. The init script now waits until thermferm is completely stopped.

Code cleanup

Version 0.9.18

Only log temperature error once. Only log temperature Ok again once. Do not log changed temperature.

Finished one-wire ds2413 output

Stop logging ghost one-wire devices.

Reboot from the panel is now restart application. The restart is working again, also via bmsapp.

Upgraded MIGRATION document.

Removed lcd-buffer create logmessage. Combined Keys and Delay states.

(0) -300 -100 -50 -30 +30 tip