Mon, 04 Nov 2019 13:19:27 +0100
Version 0.9.7. Increased the maximum fermentation temperature to 45 degrees to allow Kveik fermentations.
configure | file | annotate | diff | comparison | revisions | |
configure.ac | file | annotate | diff | comparison | revisions | |
thermferm/rdconfig.c | file | annotate | diff | comparison | revisions | |
thermferm/server.c | file | annotate | diff | comparison | revisions | |
www-thermferm/liveview.php | file | annotate | diff | comparison | revisions | |
www-thermferm/units.php | file | annotate | diff | comparison | revisions |
--- a/configure Sun Jul 07 14:28:37 2019 +0200 +++ b/configure Mon Nov 04 13:19:27 2019 +0100 @@ -2047,7 +2047,7 @@ PACKAGE="mbsePi-apps" -VERSION="0.9.6" +VERSION="0.9.7" COPYRIGHT="Copyright (C) 2014-2019 Michiel Broek, All Rights Reserved" CYEARS="2014-2019"
--- a/configure.ac Sun Jul 07 14:28:37 2019 +0200 +++ b/configure.ac Mon Nov 04 13:19:27 2019 +0100 @@ -8,7 +8,7 @@ dnl General settings dnl After changeing the version number, run autoconf! PACKAGE="mbsePi-apps" -VERSION="0.9.6" +VERSION="0.9.7" COPYRIGHT="Copyright (C) 2014-2019 Michiel Broek, All Rights Reserved" CYEARS="2014-2019" AC_SUBST(PACKAGE)
--- a/thermferm/rdconfig.c Sun Jul 07 14:28:37 2019 +0200 +++ b/thermferm/rdconfig.c Mon Nov 04 13:19:27 2019 +0100 @@ -587,7 +587,7 @@ unit->heater_wait = unit->cooler_wait = unit->fan_wait = unit->light_wait = 0; unit->heater_usage = unit->cooler_usage = unit->fan_usage = unit->light_usage = 0; unit->temp_set_min = 1.0; - unit->temp_set_max = 30.0; + unit->temp_set_max = 45.0; unit->yeast_lo = 12.0; unit->yeast_hi = 24.0; unit->prof_started = unit->prof_paused = unit->prof_primary_done = (time_t)0;
--- a/thermferm/server.c Sun Jul 07 14:28:37 2019 +0200 +++ b/thermferm/server.c Mon Nov 04 13:19:27 2019 +0100 @@ -1411,7 +1411,7 @@ unit->heater_wait = unit->cooler_wait = unit->fan_wait = unit->light_wait = 0; unit->heater_usage = unit->cooler_usage = unit->fan_usage = unit->light_usage = 0; unit->temp_set_min = 1.0; - unit->temp_set_max = 30.0; + unit->temp_set_max = 45.0; unit->prof_started = unit->prof_paused = unit->prof_primary_done = (time_t)0; unit->prof_percent = 0; unit->PID_cool = (pid_var *)malloc(sizeof(pid_var));
--- a/www-thermferm/liveview.php Sun Jul 07 14:28:37 2019 +0200 +++ b/www-thermferm/liveview.php Mon Nov 04 13:19:27 2019 +0100 @@ -135,11 +135,11 @@ if ("$air_state" == "OK") { $outstr .= ' $("#gaugeContainer_air'.$unr.'").jqxGauge({'.PHP_EOL; - $outstr .= ' min: -5, max: 35, width: 275, height: 275,'.PHP_EOL; + $outstr .= ' min: -5, max: 45, width: 275, height: 275,'.PHP_EOL; $outstr .= ' ranges: [{ startValue: -5, endValue: 0, style: { fill: \'#3399FF\', stroke: \'#3399FF\' }, endWidth: 10, startWidth: 10 },'.PHP_EOL; $outstr .= ' { startValue: 0, endValue: 16, style: { fill: \'#00CC33\', stroke: \'#00CC33\' }, endWidth: 10, startWidth: 10 },'.PHP_EOL; $outstr .= ' { startValue: 16, endValue: 24, style: { fill: \'#FCA76A\', stroke: \'#FCA76A\' }, endWidth: 10, startWidth: 10 },'.PHP_EOL; - $outstr .= ' { startValue: 24, endValue: 35, style: { fill: \'#FC6A6A\', stroke: \'#FC6A6A\' }, endWidth: 10, startWidth: 10 }],'.PHP_EOL; + $outstr .= ' { startValue: 24, endValue: 45, style: { fill: \'#FC6A6A\', stroke: \'#FC6A6A\' }, endWidth: 10, startWidth: 10 }],'.PHP_EOL; $outstr .= ' ticksMinor: { interval: 1, size: \'5%\' },'.PHP_EOL; $outstr .= ' ticksMajor: { interval: 5, size: \'9%\' },'.PHP_EOL; $outstr .= ' labels: { interval: 5 },'.PHP_EOL; @@ -152,11 +152,11 @@ if ("$beer_state" == "OK") { $outstr .= ' $(\'#gaugeContainer_beer'.$unr.'\').jqxGauge({'.PHP_EOL; - $outstr .= ' min: -5, max: 35, width: 275, height: 275,'.PHP_EOL; + $outstr .= ' min: -5, max: 45, width: 275, height: 275,'.PHP_EOL; $outstr .= ' ranges: [{ startValue: -5, endValue: 0, style: { fill: \'#3399FF\', stroke: \'#3399FF\' }, endWidth: 10, startWidth: 10 },'.PHP_EOL; $outstr .= ' { startValue: 0, endValue: 16, style: { fill: \'#00CC33\', stroke: \'#00CC33\' }, endWidth: 10, startWidth: 10 },'.PHP_EOL; $outstr .= ' { startValue: 16, endValue: 24, style: { fill: \'#FCA76A\', stroke: \'#FCA76A\' }, endWidth: 10, startWidth: 10 },'.PHP_EOL; - $outstr .= ' { startValue: 24, endValue: 35, style: { fill: \'#FC6A6A\', stroke: \'#FC6A6A\' }, endWidth: 10, startWidth: 10 }],'.PHP_EOL; + $outstr .= ' { startValue: 24, endValue: 45, style: { fill: \'#FC6A6A\', stroke: \'#FC6A6A\' }, endWidth: 10, startWidth: 10 }],'.PHP_EOL; $outstr .= ' ticksMinor: { interval: 1, size: \'5%\' },'.PHP_EOL; $outstr .= ' ticksMajor: { interval: 5, size: \'9%\' },'.PHP_EOL; $outstr .= ' labels: { interval: 5 },'.PHP_EOL;
--- a/www-thermferm/units.php Sun Jul 07 14:28:37 2019 +0200 +++ b/www-thermferm/units.php Mon Nov 04 13:19:27 2019 +0100 @@ -1,6 +1,6 @@ <?php /***************************************************************************** - * Copyright (C) 2014-2018 + * Copyright (C) 2014-2019 * * Michiel Broek <mbroek at mbse dot eu> * @@ -238,7 +238,7 @@ if ($_POST['TempSetMax'] <= $_POST['TempSetMin']) return 4; - if (($_POST['TempSetMax'] < 25) || ($_POST['TempSetMax'] > 35)) + if (($_POST['TempSetMax'] < 25) || ($_POST['TempSetMax'] > 45)) return 5; if (($_POST['TempSetMin'] < -5) || ($_POST['TempSetMin'] > 15)) @@ -296,7 +296,7 @@ break; case 4: $error = 'Temperature Maximum cannot be smaller then Temperature Minimum'; break; - case 5: $error = 'Temperature Maximum must be between 25 and 35 °C'; + case 5: $error = 'Temperature Maximum must be between 25 and 45 °C'; break; case 6: $error = 'Temperature Minimum must be between -5 and 15 °C'; break;