Version 0.9.19a6. Fixes after a short trial on the production controller. Fixed json for alternate beer termperature sensor. Fixed division by 1000 for the room temperature and humidity values. The dropdown list for devices shows the address instead of description in the list.

#ifndef	_PANEL_H
#define	_PANEL_H



/*
 * GPIO pins for the frontpanel LED and push buttons.
 */
#define	PANEL_LED	2
#define	PANEL_ENTER	4
#define	PANEL_DOWN	5
#define	PANEL_UP	6


/*
 * Key names
 */
#define	KEY_NONE	0
#define	KEY_UP		1
#define	KEY_DOWN	2
#define	KEY_ESCAPE	3
#define	KEY_ENTER	4
#define	KEY_CONFIRM	5	/* Long Enter */
#define	KEY_ALL		99


int keycheck(void);

#ifdef HAVE_WIRINGPI_H
PI_THREAD (my_panel_loop);
#else
void *my_panel_loop(void *);
#endif

#endif